Flow meter connection variations

GDS 207 compatible, standard pinout

GDS 207 compatible, alternate pinout

Three quick connect 2.8x0.8mm

Two quick connect plus ring terminal

2.54 pitch four pin header

Example images

Pinout

Specification

Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin

Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, ground on centre pin

Three 2.8x0.8mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin

Two 2.8x0.8mm pins, plus one M4 ring terminal (ground)

Single row 4 circuit 2.54 pitch pin header

Notes

  • These flow meters have the same pin configuration and pinout as the GDS 207 compatible standard pinout flow meters, but they are not compatible with the GDS 207 connector because the pin width is larger than what the GDS 207 connector is designed to accommodate.

Espresso machines

  • Nuova Simonelli

  • Victoria Arduino

  • La Spazielle

  • San Remo

  • Slayer

  • Kees Vander Westen

  • La Marzocco

    • Most models

  • Unic

  • Synesso

  • Rancilio

  • La Marzocco

    • Modbar

    • FB70

    • Strada

  • La Cimbali

Other information

Nuova Simonelli / Victoria Arduino

  • Black Eagle Gravimetric machines do not have a flow meter, so will not be compatible.

  • Pulse Jet is preinfusion and will need to be set manually by the tech team. 

La Marzocco

  • Strada does not have a service hole, so no way to feed the main cable out of the machine. Either non-compatible, or a hole needs to be drilled to accommodate the cable. 

  • KB90 Barely has enough clearance for the main cable, plus the adaptor. It can fit through needs improvement from our end, primarily through a slimline version of the adaptor. 

San Remo

  • Cafe Racer has four pole sensor

Slayer

  • 4 pole flow sensor

Synesso

  • 4 Pole Flow sensor. 

  • 'S' models internal components are Synesso standard as found in our MVP and MVP Hydra machines.

Unic

  • The group one and two flow meters are further apart than our cable split allows. Manually splitting cable is a short term fix, though refinement required. 

  • No labels