La Spazielle

  • Standard connection which does not require a cable adaptor

Nuova Simonelli / Victoria Arduino

  • Standard connection which does not require a cable adaptor

  • Black Eagle Gravimetric machines do not have a flow meter, so will not be compatible.

  • Pulse Jet is preinfusion and will need to be set manually by the tech team. 

La Marzocco

  • Standard Gicar, though alternate pin out adapter required. 

  • Modbar, FB70  and strada models use the ‘lug’ adaptor that Rancilio use. 

  • Strada does not have a service hole, so no way to feed the main cable out of the machine. Either non-compatible, or a hole needs to be drilled to accommodate the cable. 

  • Kb90 Barely has enough clearance for the main cable, plus the adaptor. It can fit through needs improvement from our end, primarily through a slimline version of the adaptor. 

San Remo

  • Standard connection which does not require a cable adaptor

  • Cafe Racer has four pole sensor

Rancilio 

  • Requires the Two terminal plus ground lug adaptor. 

Slayer

  • 4 pole flow sensor

  • Standard connection which does not require a cable adaptor

  • Four pole sensor will so will need confirmation data is accurate. 

Synesso

  • 4 Pole Flow sensor. 

  • Standard connection which does not require a cable adaptor. Flowmeter pins are thicker and may require quick connects(TBC)

  • 'S' models internal components are Synesso standard as found in our MVP and MVP Hydra machines.

Unic

  • Standard connection though does require the alternate pinout adaptor. 

  • the group one and two flow meters are further apart than our cable split allows. Manually splitting cable is a short term fix, though refinement required. 

La Cimbali

  • Four pin header adaptor required. 

Kees Vander Westen

  • Standard Flow sensor, so no adaptor required. 