<TODO update and simplify this page info from /wiki/spaces/TS/pages/4784263:
UK / EU
CE - Covering:
Safety (EN 62368-1)
EMC (EN 55032, EN 55035)
Radio equipment (WiFi / Bluetooth) <TODO add EU radio equipment standard <What standard is associated with the Radio Equipment Directive?>
RoHS <TODO add EU RoHS standard>
WEEE - We would expect a EU based manufacturer to handle any WEEE obligations for products shipped to EU locations, and preferably also UK locations
Australia / New Zealand
RCM - Covering: Safety, EMC, radio equipment (WiFi / Bluetooth)
RCM compliance is based off the same standards that the EU requires for safety and EMC <TODO confirm if this is the same for the radio equipment standards>
Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section - https://www.erac.gov.au/
Registration with EESS (Electrical Equipment Safety System) - https://www.eess.gov.au/
United States / Canada
<TODO Is this required?: Safety: UL listed for US and Canada (UL/IEC 62368-1)>
EMC:
<TODO FCC/Industry Canada registration approval requirement>
Compliance with:
FCC Part 15 Subparts A + B
ICES-003
Radio equipment:
<TODO FCC/Industry Canada registration approval requirement>
Compliance with:
FCC Part 15 Subparts C-F, H
<TODO Industry Canada Radio Apparatus certifications under Category I>
>
Australia / New Zealand
Category | Requirement | Supporting evidence | Last updated |
---|---|---|---|
RCM | Product description |
| |
RCM | RCM Supplier Declaration of Conformity (SDoC) | TODO | |
Safety | Safety test report demonstrating compliance with AS/NZS 62368-1:2018 | TODO | |
Electromagnetic compatibility | Electromagnetic compatibility (EMC) Emissions test report demonstrating compliance with EN 55032: 2015 + A11:2020 | ||
Electromagnetic compatibility | Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section | TODO | |
Safety | <TODO determine external power supply risk class and if this is required> External power supply registration with EESS (Electrical Equipment Safety System) | TODO | |
Energy efficiency | External power supply registration with E3 Program (Equipment Energy Efficiency) |
Europe / UK
Category | Requirement | Supporting evidence | Last updated |
---|---|---|---|
CE | Product description | ||
CE | CE Supplier Declaration of Conformity (SDoC) | TODO | |
Safety | <TODO reword this to reference the EU directive> Safety test report demonstrating compliance with AS/NZS 62368-1:2018 | TODO | |
Electromagnetic compatibility | <TODO reword this to reference the EU directive> Electromagnetic compatibility (EMC) Emissions test report demonstrating compliance with EN 55032: 2015 + A11:2020 | ||
Electromagnetic compatibility | Electromagnetic compatibility immunity test report demonstrating compliance with EN 55035: 2017 + A11:2020, EN 61000-4-2,3,4,5,6,8,11, and EN 61000-3-2,3 |
| |
Energy efficiency | <TODO What are there energy efficiency compliance requirements for the EU / UK?> | ||
Restriction of Hazardous Substances (RoHS) | <TODO reference EU directive / standards> | ||
Waste Electrical and Electronic Equipment (WEEE) | <TODO reference EU directive / standards> |
USA / Canada
Category | Component | Requirement | Supporting evidence | Last updated |
---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B | ||
Electromagnetic compatibility | Flow Gateway device | FCC SDoC (Supplier Declaration of Conformity) <TODO get requirements list from EMC Technologies report> | ||
Electromagnetic compatibility | External power supply | OEM provided FCC SDoC (Supplier Declaration of Conformity) | ||
Electromagnetic compatibility | Flow Gateway device with external power supply | Display required FCC warnings in the user manual <TODO what are the required FCC warnings?> | ||
Safety | Flow Gateway device | Safety test report demonstrating compliance with UL 62368-1:2019 | ||
<How do we demonstrate that the external power supply complies with the safety requirements?> <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?> | ||||
<TODO Are there energy efficiency compliance requirements for the USA?> | ||||
<TODO what do we have to do to demonstrate RoHS compliance?> |