Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 18 Next »


Also see https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGCI/pages/594313243/Flow+meter+cable+variations

Nuova Simonelli / Victoria Arduino

  • Black Eagle Gravimetric machines do not have a flow meter, so will not be compatible.

  • Pulse Jet is pre-infusion and will need to be set manually by the tech team. 

La Marzocco

  • Strada services hole for routing flow cable can be exposed by removing back panel of machine. 

  • KB90 does not have enough clearance for standard GDS207 flow meter connectors. Use Flow KB90 cable with LM low profile connectors or Flow Quick Disconnect cable instead.

San Remo

  • All San Remo F18's, Cafe Racers, and Operas have 4 pole flow meters

  • F18’s have a soft pre-infusion cycle that will require pre-infusion detection enabled.

Slayer

  • Four pole flow meter

Synesso

  • Four pole flow meter

  • 'S' models internal components are Synesso standard as found in our MVP and MVP Hydra machines.

Unic

  • The group one and two flow meters are further apart than our cable split allows. Manually splitting cable is a short term fix, though refinement required. 