Table of Contents |
---|
<TODO update and simplify this page info from /wiki/spaces/TS/pages/4784263:
UK / EU
CE - Covering:
Electrical safety (EN 62368-1)
EMC (EN 55032, EN 55035)
Radio equipment (WiFi / Bluetooth) <TODO add EU radio equipment standard <What standard is associated with the Radio Equipment Directive?>
RoHS <TODO add EU RoHS standard>
WEEE - We would expect a EU based manufacturer to handle any WEEE obligations for products shipped to EU locations, and preferably also UK locations
Australia / New Zealand
RCM - Covering: Electrical safety, EMC, radio equipment (WiFi / Bluetooth)
...
Table of Contents |
---|
Australia / New Zealand
Category | Requirement | Supporting evidence | Last updated |
---|---|---|---|
RCM | Product description |
| |
RCM | RCM Supplier Declaration of Conformity (SDoC) |
| |
RCM | RCM mark displayed on Flow Gateway and external power supply |
| |
Safety | Test reports demonstrating compliance with AS/NZS 62368-1:2018 |
| |
Electromagnetic compatibility (Emissions) | Test reports demonstrating compliance with EN 55032: 2015 + A11:2020 | ||
Electromagnetic compatibility | Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section |
...
...
| |
Safety | External power supply registration with EESS (Electrical Equipment Safety System) |
...
as risk level 3 equipment |
United States / Canada
<TODO Is this required?: Electrical safety: UL listed for US and Canada (UL/IEC 62368-1)>
EMC:
<TODO FCC/Industry Canada registration approval requirement>
Compliance with:
FCC Part 15 Subparts A + B
ICES-003
Radio equipment:
<TODO FCC/Industry Canada registration approval requirement>
Compliance with:
FCC Part 15 Subparts C-F, H
<TODO Industry Canada Radio Apparatus certifications under Category I>
>
Australia / New Zealand
...
Category
...
Component
...
Requirement
...
Status
...
Supporting evidence
...
Last updated
...
Electromagnetic compatibility
...
Flow Gateway device
...
Product description
...
Electromagnetic compatibility
...
Flow Gateway device with external power supply
...
Electromagnetic compatibility emissions test report demonstrating compliance with <TODO EMC Tech referenced “AS/NZS CISPR 32” or Spectrum lab referenced “EN 55032: 2015 + A11”?>
...
Electromagnetic compatibility
...
Flow Gateway device
...
SDoC (Supplier Declaration of Conformity)
...
Electromagnetic compatibility
...
External power supply
...
OEM provided SDoC (Supplier Declaration of Conformity)
...
Electromagnetic compatibility
...
Flow Gateway device with external power supply
...
Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section
https://www.erac.gov.au/
...
Electrical safety
...
Flow Gateway device
...
Electrical safety test report demonstrating compliance with AS/NZS 62368.1:2018
...
Electrical safety
...
External power supply
...
OEM provided test report demonstrating compliance with AS/NZS 62368.1:2018 or AS/NZS 60950.1:2015 <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current test report and/or documents for AU?>
...
Electrical safety
...
External power supply
...
Registration with EESS (Electrical Equipment Safety System)
https://www.eess.gov.au/
...
Energy efficiency
...
External power supply
...
Registration with E3 Program (Equipment Energy Efficiency)
https://www.energyrating.gov.au/
...
<TODO is RoHS required for AU/NZ, and if so what do we have to do to demonstrate RoHS compliance?>
Europe / UK
...
Category
...
Component
...
Requirement
...
Status
...
Supporting evidence
...
Last updated
...
Electromagnetic compatibility
...
Flow Gateway device with external power supply
...
Electromagnetic compatibility emissions test report demonstrating compliance with EN 55032:2015+A11
...
Electromagnetic compatibility
...
Flow Gateway device with external power supply
...
Electromagnetic compatibility immunity test report demonstrating compliance with EN 55035:2017
...
Electrical safety
...
Flow Gateway device
...
Electrical safety test report demonstrating compliance with EN 62368-1:2020
...
Electromagnetic compatibility and Electrical safety
...
Flow Gateway device
...
CE Declaration of Conformity for electromagnetic compatibility and electrical safety
...
Electrical safety
...
External power supply
...
OEM provided CE Declaration of Conformity for electromagnetic compatibility and electrical safety <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current CE Declaration of Conformity?>
...
<TODO What are there energy efficiency compliance requirements for the EU?>
...
<TODO what do we have to do to demonstrate RoHS compliance?>
...
<TODO Is the device required to be WEEE compliant (or just the power supply)?>
...
<TODO what do we have to do to verify the power supplies WEEE compliance?>
USA / Canada
Category | Component | Requirement | Status | Supporting evidence | Last updated |
---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#EESS-registration-database |
| ||
Energy efficiency | External power supply certified to class V or VI and marked accordingly, demonstrating compliance with AS/NZS 4665.2:2005 A1 | ||||
Energy efficiency | External power supply registered with the E3 Program (Equipment Energy Efficiency) |
Europe / UK
Category | Requirement | Supporting evidence | Last updated |
---|---|---|---|
CE | Product description | ||
CE | CE Supplier Declaration of Conformity (SDoC) |
| |
CE | CE mark displayed on Flow Gateway and external power supply |
| |
Safety | Test reports certifying to standards:
demonstrating compliance with the EU legislation: 2014/35/EU Low Voltage (LVD) Directive |
| |
Electromagnetic compatibility (Emissions and susceptibility) | Test reports certifying to standards:
demonstrating compliance with the EU legislation: 2014/30/EU Electromagnetic Compatibility (EMC) Directive | ||
Energy efficiency | External power supply certified to class VI in alignment with
demonstrating compliance with the EU legislation: 2009/125/EC Ecodesign Directive |
| |
Restriction of Hazardous Substances (RoHS) | Certificates / declarations for input components, in conformance with standard:
demonstrating compliance with the EU legislation: 2011/65/EU Restriction of Hazardous Substances Directive (RoHS) Directive |
| |
Waste Electrical and Electronic Equipment (WEEE) | Registration with country specific schemes demonstrating compliance with the EU legislation: 2012/19/EU Waste Electrical and Electronic Equipment (WEEE) Directive | UK |
USA / Canada
Category | Requirement | Supporting evidence | Last updated | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FCC | FCC Supplier Declaration of Conformity (SDoC) | TODO | ||||||||||||||||
Safety | Test reports certifying to standard IEC 62368-1:2014 (Second Edition) |
| ||||||||||||||||
Electromagnetic compatibility (Emissions) | Test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B | Electromagnetic compatibility | Flow Gateway device | FCC SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | External power supply | OEM provided FCC SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | Flow Gateway device with external power supply | Display required FCC warnings in the user manual <TODO what are the required FCC warnings?> | Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with UL 62368-1:2019 | <How do we demonstrate that the external power supply complies with the electrical safety requirements?> <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?> | <TODO Are there energy efficiency compliance requirements for the USA?> | <TODO what do we have to do to demonstrate RoHS compliance?>, and Industry Canada ICES-003 |
| |
Energy efficiency | External power supply certified to US Department of Energy (DOE) External Power Supply (EPS) standard - Level VI |
| ||||||||||||||||
Restriction of Hazardous Substances (RoHS) | Certificates / declarations for input components, demonstrating compliance with the EU RoHS Directive 2011/65/EU (Compliance with the EU directive is required by some states in the USA) |
|