Australia / New Zealand
Category | Component | RequirementStatus | Supporting evidence | Last updated | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device | Product description | Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with <TODO EMC Tech referenced “AS/NZS CISPR 32” or Spectrum lab referenced “EN 55032: 2015 + A11”?> | Electromagnetic compatibility | Flow Gateway device | SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | External power supply | OEM provided SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | Flow Gateway device with external power supplyRCM | Product description |
| |
RCM | RCM Supplier Declaration of Conformity (SDoC) |
| ||||||||||||||
RCM | RCM mark displayed on Flow Gateway and external power supply |
| ||||||||||||||
Safety | Test reports demonstrating compliance with AS/NZS 62368-1:2018 |
| ||||||||||||||
Electromagnetic compatibility (Emissions) | Test reports demonstrating compliance with EN 55032: 2015 + A11:2020 | |||||||||||||||
Electromagnetic compatibility | Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section | Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with AS/NZS 62368.1:2018 | Electrical safety | External power supply | OEM provided test report demonstrating compliance with AS/NZS 62368.1:2018 or AS/NZS 60950.1:2015 <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current test report and/or documents for AU?> | Electrical safety | External power supply |
| ||||||
Safety | External power supply registration with EESS (Electrical Equipment Safety System) as risk level 3 equipment |
| ||||||||||||||
Energy efficiency | External power supply Registration with certified to class V or VI and marked accordingly, demonstrating compliance with AS/NZS 4665.2:2005 A1 | |||||||||||||||
Energy efficiency | External power supply registered with the E3 Program (Equipment Energy Efficiency) |
Europe / UK
CategoryComponent | RequirementStatus | Supporting evidence | Last updated | Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CE | Product description | ||||||||||||||||
CE | CE Supplier Declaration of Conformity (SDoC) |
| |||||||||||||||
CE | CE mark displayed on Flow Gateway and external power supply |
| |||||||||||||||
Safety | Test reports certifying to standards:
demonstrating compliance with the EU legislation: 2014/35/EU Low Voltage (LVD) Directive |
| |||||||||||||||
Electromagnetic compatibility (Emissions and susceptibility) | Test reports certifying to standards:
| Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility immunity test report demonstrating compliance with
| Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with EN 62368-1:2020 | Electromagnetic compatibility and Electrical safety | Flow Gateway device | CE Declaration of Conformity for electromagnetic compatibility and electrical safety | Electrical safety | External power supply | OEM provided CE Declaration of Conformity for electromagnetic compatibility and electrical safety <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current CE Declaration of Conformity?> | <TODO What are there energy efficiency compliance requirements for the EU?> | <TODO what do we have to do to demonstrate RoHS compliance?> | <TODO Is the device required to be WEEE compliant (or just the power supply)?> | <TODO what do we have to do to verify the power supplies WEEE compliance?> |
USA / Canada
Category | Component | Requirement | Status | Supporting evidence | Last updated |
---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test
demonstrating compliance with the EU legislation: 2014/30/EU Electromagnetic Compatibility (EMC) Directive | |||
Energy efficiency | External power supply certified to class VI in alignment with
demonstrating compliance with the EU legislation: 2009/125/EC Ecodesign Directive |
| |||
Restriction of Hazardous Substances (RoHS) | Certificates / declarations for input components, in conformance with standard:
demonstrating compliance with the EU legislation: 2011/65/EU Restriction of Hazardous Substances Directive (RoHS) Directive |
| |||
Waste Electrical and Electronic Equipment (WEEE) | Registration with country specific schemes demonstrating compliance with the EU legislation: 2012/19/EU Waste Electrical and Electronic Equipment (WEEE) Directive | UK |
USA / Canada
Category | Requirement | Supporting evidence | Last updated | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FCC | FCC Supplier Declaration of Conformity (SDoC) | TODO | ||||||||||||||||
Safety | Test reports certifying to standard IEC 62368-1:2014 (Second Edition) |
| ||||||||||||||||
Electromagnetic compatibility (Emissions) | Test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B | Electromagnetic compatibility | Flow Gateway device | FCC SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | External power supply | OEM provided FCC SDoC (Supplier Declaration of Conformity) | Electromagnetic compatibility | Flow Gateway device with external power supply | Display required FCC warnings in the user manual <TODO what are the required FCC warnings?> | Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with UL 62368-1:2019 | <How do we demonstrate that the external power supply complies with the electrical safety requirements?> <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?> | <TODO Are there energy efficiency compliance requirements for the USA?> | <TODO what do we have to do to demonstrate RoHS compliance?>, and Industry Canada ICES-003 |
| |
Energy efficiency | External power supply certified to US Department of Energy (DOE) External Power Supply (EPS) standard - Level VI |
| ||||||||||||||||
Restriction of Hazardous Substances (RoHS) | Certificates / declarations for input components, demonstrating compliance with the EU RoHS Directive 2011/65/EU (Compliance with the EU directive is required by some states in the USA) |
|