Requirements

CategoryComponent

RequirementStatus

Supporting evidence

Last updated

Electromagnetic compatibility

Flow Gateway device

Product description

Electromagnetic compatibility

Flow Gateway device with external power supply

Electromagnetic compatibility emissions test report demonstrating compliance with <TODO EMC Tech referenced “AS/NZS CISPR 32” or Spectrum lab referenced “EN 55032: 2015 + A11”?>

Electromagnetic compatibility

Flow Gateway device

SDoC (Supplier Declaration of Conformity)

Electromagnetic compatibility

External power supply

OEM provided SDoC (Supplier Declaration of Conformity)

Electromagnetic compatibility

Flow Gateway device with external power supplyRCM

Product description

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC

RCM

RCM Supplier Declaration of Conformity (SDoC)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#RCM-Supplier-Declaration-of-Conformity-(SDoC)

RCM

RCM mark displayed on Flow Gateway and external power supply

Product marking

Safety

Test reports demonstrating compliance with AS/NZS 62368-1:2018

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

Electromagnetic compatibility

(Emissions)

Test reports demonstrating compliance with EN 55032: 2015 + A11:2020

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Electromagnetic-compatibility-(EMC)-certifications

Electromagnetic compatibility

Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section
https://www.erac.gov.au/

Electrical safety

Flow Gateway device

Electrical safety test report demonstrating compliance with AS/NZS 62368.1:2018

Electrical safety

External power supply

OEM provided test report demonstrating compliance with AS/NZS 62368.1:2018 or AS/NZS 60950.1:2015 <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current test report and/or documents for AU?>

Electrical safety

External power supply

Registration https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#ERAC-(Electrical-Regulatory-Authorities-Council)-responsible-supplier-directory

Safety

External power supply registration with EESS (Electrical Equipment Safety System) as risk level 3 equipment
https://www.eess.gov.au/

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#EESS-registration-database

Energy efficiency

External power supply Registration with certified to class V or VI and marked accordingly, demonstrating compliance with AS/NZS 4665.2:2005 A1

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Manufacturer-CE-Declaration-of-Conformity.2

Energy efficiency

External power supply registered with the E3 Program (Equipment Energy Efficiency)
https://www.energyrating.gov.au/

<TODO is RoHS required for AU/NZ, and if so what do we have to do to demonstrate RoHS compliance?>

Product marking

...

Category

...

Component

...

Mark

...

Electromagnetic compatibility / Electrical safety

...

Flow Gateway device

...

RCM (Regulatory Compliance Mark)

...

Electromagnetic compatibility / Electrical safety

...

External power supply

...

RCM (Regulatory Compliance Mark)

...

Energy efficiency

...

External power supply

...

External power supply efficiency level mark

...

<TODO Is a RoHS mark required for the device, and if so which one?>

...

<TODO Is a RoHS mark required for the power supply, and if so which one?>

Europe / UK

Requirements

...

Category

...

Component

...

Requirement

...

Status

...

Supporting evidence

...

Last updated

...

Electromagnetic compatibility

...

Flow Gateway device with external power supply

...

Electromagnetic compatibility emissions test report demonstrating compliance with EN 55032:2015+A11

...

Electromagnetic compatibility

...

Flow Gateway device with external power supply

...

Electromagnetic compatibility immunity test report demonstrating compliance with EN 55035:2017

...

Electrical safety

...

Flow Gateway device

...

Electrical safety test report demonstrating compliance with EN 62368-1:2020

...

Electromagnetic compatibility and Electrical safety

...

Flow Gateway device

...

CE Declaration of Conformity for electromagnetic compatibility and electrical safety

...

Electrical safety

...

External power supply

...

OEM provided CE Declaration of Conformity for electromagnetic compatibility and electrical safety <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current CE Declaration of Conformity?>

...

<TODO What are there energy efficiency compliance requirements for the EU?>

...

<TODO what do we have to do to demonstrate RoHS compliance?>

...

<TODO Is the device required to be WEEE compliant (or just the power supply)?>

...

<TODO what do we have to do to verify the power supplies WEEE compliance?>

Product marking

...

Category

...

Component

...

Mark

...

Electromagnetic compatibility / Electrical safety

...

Flow Gateway device

...

CE

...

Electromagnetic compatibility / Electrical safety

...

External power supply

...

CE

...

<Is External power supply efficiency level mark required?>

...

<Is WEEE mark required for device>

...

<Is WEEE mark required for power supply>

USA / Canada

Requirements

Category

Component

Requirement

Status

Supporting evidence

Last updated

Electromagnetic compatibility

Flow Gateway device with external power supply

Electromagnetic compatibility emissions test https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Australia-E3-Program-(Equipment-Energy-Efficiency)-registration

Europe / UK

Category

Requirement

Supporting evidence

Last updated

CE

Product description

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC

CE

CE Supplier Declaration of Conformity (SDoC)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#CE-Supplier-Declaration-of-Conformity-(SDoC)

CE

CE mark displayed on Flow Gateway and external power supply

Product marking

Safety

Test reports certifying to standards:

  • EN 62368-1:2014 + A11:2017

demonstrating compliance with the EU legislation:

2014/35/EU Low Voltage (LVD) Directive

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

Electromagnetic compatibility (Emissions and susceptibility)

Test reports certifying to standards:

  • EN 55032: 2015 + A11:2020

  • EN 55035: 2017 + A11:2020

  • EN 61000-4-2,3,4,5,6,8,11

  • EN 61000-3-2,3

demonstrating compliance with the EU legislation:

2014/30/EU Electromagnetic Compatibility (EMC) Directive

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Electromagnetic-compatibility-(EMC)-certifications

Energy efficiency

External power supply certified to class VI in alignment with

  • Commission Regulation (EU) 2019/1782

demonstrating compliance with the EU legislation:

2009/125/EC Ecodesign Directive

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Manufacturer-CE-Declaration-of-Conformity.2

Restriction of Hazardous Substances (RoHS)

Certificates / declarations for input components, in conformance with standard:

  • EN 50581:2012

demonstrating compliance with the EU legislation:

2011/65/EU Restriction of Hazardous Substances Directive (RoHS) Directive

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Restriction-of-Hazardous-Substances-(RoHS)-declarations

Waste Electrical and Electronic Equipment (WEEE)

Registration with country specific schemes demonstrating compliance with the EU legislation:

2012/19/EU Waste Electrical and Electronic Equipment (WEEE) Directive

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Waste-Electrical-and-Electronic-Equipment-(WEEE)

UK

USA / Canada

Category

Requirement

Supporting evidence

Last updated

FCC

FCC Supplier Declaration of Conformity (SDoC)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#FCC-Supplier-Declaration-of-Conformity-(SDoC)

TODO

Safety

Test reports certifying to standard IEC 62368-1:2014 (Second Edition)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

Electromagnetic compatibility (Emissions)

Test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B

Electromagnetic compatibility

Flow Gateway device

FCC SDoC (Supplier Declaration of Conformity)

Electromagnetic compatibility

External power supply

OEM provided FCC SDoC (Supplier Declaration of Conformity)

Electromagnetic compatibility

Flow Gateway device with external power supply

Display required FCC warnings in the user manual <TODO what are the required FCC warnings?>

Electrical safety

Flow Gateway device

Electrical safety test report demonstrating compliance with UL 62368-1:2019

<How do we demonstrate that the external power supply complies with the electrical safety requirements?>

<TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?>

<TODO Are there energy efficiency compliance requirements for the USA?>

<TODO what do we have to do to demonstrate RoHS compliance?>

Product marking

Category

Component

Mark

<If we don’t need to register the device with FCC, can/should we use the FCC mark on the device still?>

Electromagnetic compatibility

External power supply

FCC

<TODO is a electrical safety mark (UL?) required for the device>

<TODO what electrical safety mark (UL?) is required for power supply>

<Is External power supply efficiency level mark required?>

<TODO Is the RoHS mark required for device, and if so which one?>

<TODO Is the RoHS mark required for power supply, and if so which one?>, and Industry Canada ICES-003

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Electromagnetic-compatibility-(EMC)-certifications

Energy efficiency

External power supply certified to US Department of Energy (DOE) External Power Supply (EPS) standard - Level VI

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#USA-DOE-Compliance-Certification-Database

Restriction of Hazardous Substances (RoHS)

Certificates / declarations for input components, demonstrating compliance with the EU RoHS Directive 2011/65/EU (Compliance with the EU directive is required by some states in the USA)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Restriction-of-Hazardous-Substances-(RoHS)-declarations