Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents

...

Child pages (Children Display)
depth3

Also see Flow meter

...

cable variations

...

GDS 207 compatible, standard pinout

...

GDS 207 compatible, alternate pinout

...

Three quick connect 2.8x0.8mm

...

Two quick connect plus ring terminal

...

2.54 pitch four pin header

...

Example images

...

<TODO get better quality image>

...

Pinout

...

Image Removed

Image Removed

...

Applicable espresso machines

...

  • Nuova Simonelli

  • Victoria Arduino

  • Sanremo

  • Slayer

  • Kees Vander Westen

  • Wega

  • Dalla Corte

...

  • La Marzocco

    • Most models

  • Unic

...

  • Synesso

<TODO: Confirm:

  • La Spazielle

  • TBC: Appia

>

...

  • Rancilio

  • La Marzocco

    • Modbar

    • FB70

    • Strada AV

...

  • La Cimbali

  • Faema

...

Specification

...

Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin

...

Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, ground on centre pin

...

Three 2.8x0.8mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin

...

Two 2.8x0.8mm pins, plus one M4 ring terminal (ground)

...

Single row 4 circuit 2.54 pitch pin header

...

Flow meter manufacturer

...

Gicar

...

Gicar

...

Digmesa

...

Gicar

...

TBC

...

Notes

...

  • These flow meters have the same pin configuration and pinout as the GDS 207 compatible standard pinout flow meters, but they are not compatible with the GDS 207 connector because the pin thickness is larger than what the GDS 207 connector is designed to accommodate.

Other information

Nuova Simonelli / Victoria Arduino

Manufacturer

Models

Notes

Nuova Simonelli

Appia II

Auralia

Auralia II

Auralia Digit

Victoria Arduino

White Eagle

Black Eagle

Eagle One

  • Black Eagle Gravimetric machines do not have a flow meter, so will not be compatible.

  • Pulse Jet is

...

  • pre-infusion and will need to be set manually by the tech team. 

La Marzocco

Linea Classic

GB5

Strada AV

Strada ABR

Linea PB

KB90

  • Strada does not have a service hole, so no way to feed the main cable out of the machine. Either non-compatible, or a hole needs to be drilled to accommodate the cable. 

  • KB90 Barely has enough clearance for the main cable, plus the adaptor. It can fit through needs improvement from our end, primarily through a slimline version of the adaptor. 

San Remo

  • Cafe Racer has four pole flow meter

Slayer

KB90 ABR

  • Strada services hole for routing flow cable can be exposed by removing back panel of machine. 

  • KB90 does not have enough clearance for standard GDS207 flow meter connectors. Use Flow KB90 cable with LM low profile connectors or Flow Quick Disconnect cable instead.

San Remo

F18

Cafe Racer

Zoe

  • All San Remo F18's, Cafe Racers, and Operas have 4 pole flow meters

  • F18’s have a soft pre-infusion cycle that will require pre-infusion detection enabled.

Slayer

EP

LP

  • Four pole flow meter

Synesso

MVP

MVP Hydra

  • Four pole flow meter

  • 'S' models internal components are Synesso standard as found in our MVP and MVP Hydra machines.

Unic

Stella Di Caffe

Mira

Classic

  • The group one and two flow meters are further apart than our cable split allows. Manually splitting cable is a short term fix, though refinement required. 

La Spaziale

S9

S50

La San Marco

DTC

Rancilio

Epoca

Classe 5

Classe 11

Modbar

EP

Ruggero

Steam Hammer

Wega

Polaris Tron

Faema

La Cimbali

Kees Vander Western

??

Can be a bit of a stretch to get one Flow cable across both flow meters. Suggested workaround is to use 2 Flow cables, one for each flow meter

Image from iOS.MP4