Table of Contents |
---|
Flow meter connection variations
...
GDS 207 compatible, standard pinout
...
GDS 207 compatible, alternate pinout
...
Three quick connect 2.8x0.8mm
...
Two quick connect plus ring terminal
...
2.54 pitch four pin header
...
Example images
...
<TODO get better quality image>
...
Pinout
...
...
Applicable espresso machines
...
Nuova Simonelli
Victoria Arduino
Sanremo
Slayer
Kees Vander Westen
Wega
Dalla Corte
La Spazielle
<TODO TBC: Appia>
...
La Marzocco
Most models
Unic
...
Synesso
...
Rancilio
La Marzocco
Modbar
FB70
Strada AV
...
La Cimbali
Faema
...
Flow Gateway cables required
...
Per two groupheads:
Two grouphead Flow meter cable - DIN 43650 form C 9.4mm
...
Per two groupheads:
Two grouphead Flow meter cable - DIN 43650 form C 9.4mm
Two grouphead Flow meter cable - Alternate pinout adapter
...
Coming soon
Per two groupheads:
Two grouphead Flow meter cable - Three quick connect 2.8x0.8mm
...
Option A
Per two groupheads:
Two grouphead Flow meter cable - DIN 43650 form C 9.4mm
Per grouphead:
Two quick connect plus ring terminal adaptor
Option B (Coming soon)
Per two groupheads:
Two grouphead Flow meter cable - Two quick connect plus ring terminal (per two groupheads)
...
Option A
Per two groupheads:
Two grouphead Flow meter cable - DIN 43650 form C 9.4mm
Per grouphead:
2.54 pitch four pin header adaptor
Option B (Coming soon)
Per two groupheads:
Two grouphead Flow meter cable - 2.54 pitch four pin header
...
Flow meter connection specification
...
Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin
...
Three 2.8x0.51mm pins in DIN 43650 form C 9.4mm configuration, ground on centre pin
...
Three 2.8x0.8mm pins in DIN 43650 form C 9.4mm configuration, signal on centre pin
...
Two 2.8x0.8mm pins, plus one M4 ring terminal (ground)
...
Single row 4 circuit 2.54 pitch pin header
...
Flow meter manufacturer
...
Gicar
...
Gicar
...
Digmesa
...
Gicar
...
TBC
...
Notes
...
These flow meters have the same pin configuration and pinout as the GDS 207 compatible standard pinout flow meters, but they are not compatible with the GDS 207 connector because the pin thickness is larger than what the GDS 207 connector is designed to accommodate.
...
Child pages (Children Display) | ||
---|---|---|
|
Nuova Simonelli / Victoria Arduino
Black Eagle Gravimetric machines do not have a flow meter, so will not be compatible.
Pulse Jet is preinfusion and will need to be set manually by the tech team.
La Marzocco
Strada does not have a service hole, so no way to feed the main cable out of the machine. Either non-compatible, or a hole needs to be drilled to accommodate the cable.
KB90 Barely has enough clearance for the main cable, plus the adaptor. It can fit through needs improvement from our end, primarily through a slimline version of the adaptor.
San Remo
Cafe Racer has four pole flow meter
Slayer
Four pole flow meter
Synesso
Four pole flow meter
'S' models internal components are Synesso standard as found in our MVP and MVP Hydra machines.
Unic