<TODO update and simplify this page info from /wiki/spaces/TS/pages/4784263:

UK / EU

CE - Covering:

...

Safety (EN 62368-1)

...

EMC (EN 55032, EN 55035)

...

...

RoHS <TODO add EU RoHS standard>

...

WEEE - We would expect a EU based manufacturer to handle any WEEE obligations for products shipped to EU locations, and preferably also UK locations

Australia / New Zealand

...

  • RCM compliance is based off the same standards that the EU requires for safety and EMC <TODO confirm if this is the same for the radio equipment standards>

  • Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section - https://www.erac.gov.au/

  • Registration with EESS (Electrical Equipment Safety System) - https://www.eess.gov.au/

United States / Canada

<TODO Is this required?: Safety: UL listed for US and Canada (UL/IEC 62368-1)>

...

EMC:

  • <TODO FCC/Industry Canada registration approval requirement>

  • Compliance with:

    • FCC Part 15 Subparts A + B

    • ICES-003

Radio equipment:

...

<TODO FCC/Industry Canada registration approval requirement>

Compliance with:

...

FCC Part 15 Subparts C-F, H

...

Category

...

Australia / New Zealand

Category

Requirement

Supporting evidence

Last updated

RCM

Product description

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC

RCM

RCM Supplier Declaration of Conformity (SDoC)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#RCM-Supplier-Declaration-of-Conformity-(SDoC)

TODO

RCM

RCM mark displayed on Flow Gateway and external power supply

Product marking

TODO

Safety

Test reports demonstrating compliance with AS/NZS 62368-1:2018

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

TODO

Electromagnetic compatibility

(Emissions)

Test reports demonstrating compliance with EN 55032: 2015 + A11:2020

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Electromagnetic-compatibility-(EMC)

Electromagnetic compatibility

Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section
https://www.erac.gov.au/

TODO

TODO

Safety

<TODO determine external power supply risk class and if this is required>

External power supply registration with EESS (Electrical Equipment Safety System)
https://www.eess.gov.au/

TODO

TODO

Energy efficiency

External power supply certified to class V or VI and marked accordingly, demonstrating compliance with AS/NZS 4665.2:2005 A1

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Manufacturer-CE-Declaration-of-Conformity.2

Energy efficiency

External power supply registered with the E3 Program (Equipment Energy Efficiency)
https://www.energyrating.gov.au/

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Australia-E3-Program-(Equipment-Energy-Efficiency)-registration

...

Category

Requirement

Supporting evidence

Last updated

CE

Product description

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC

CE

CE Supplier Declaration of Conformity (SDoC)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#CE-Supplier-Declaration-of-Conformity-(SDoC)

TODO

CE

CE mark displayed on Flow Gateway and external power supply

Product marking

TODO

Safety

Test reports certifying to standard EN 62368-1, demonstrating compliance with the EU Low Voltage Directive (LVD) 2014/35/EU

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

TODO

Electromagnetic compatibility (Emissions and susceptibility)

Test reports certifying to standards:

  • EN 55032: 2015 + A11:2020

  • EN 55035: 2017 + A11:2020

  • EN 61000-4-2,3,4,5,6,8,11

  • EN 61000-3-2,3

demonstrating compliance with the EU Electromagnetic Compatibility (EMC) Directive 2014/30/EU

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Electromagnetic-compatibility-(EMC)

Energy efficiency

External power supply certified to class VI (2019/1782), demonstrating compliance with the EU Ecodesign Directive 2009/125/EC

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Manufacturer-CE-Declaration-of-Conformity.2

Restriction of Hazardous Substances (RoHS)

Certificates / declarations for input components, demonstrating compliance with the EU RoHS Directive 2011/65/EU

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Restriction-of-Hazardous-Substances-(RoHS)-declarations

TODO

Waste Electrical and Electronic Equipment (WEEE)

<TODO registration with country specific schemes> demonstrating compliance with the EU WEEE Directive 2012/19/EU

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Waste-Electrical-and-Electronic-Equipment-(WEEE)

TODO

USA / Canada

CategoryComponent

Requirement

Supporting evidence

Last updated

Electromagnetic compatibility

Flow Gateway device with external power supply

Electromagnetic compatibility emissions Safety

Safety test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B

Electromagnetic compatibility

Flow Gateway deviceUL 62368-1:2019

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

TODO

FCC

FCC SDoC (Supplier Declaration of Conformity)

<TODO get requirements list from EMC Technologies report>

Electromagnetic compatibility

External power supply

OEM provided FCC SDoC (Supplier Declaration of Conformity)

Electromagnetic compatibility

Flow Gateway device with external power supplyhttps://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#FCC-Supplier-Declaration-of-Conformity-(SDoC)

TODO

FCC

Display required FCC warnings in the user manual <TODO what are the required FCC warnings?>

TODO

TODO

Safety

Flow Gateway device

Safety test report demonstrating compliance with UL 62368-1:2019

<How do we demonstrate that the external power supply complies with the safety requirements?>

<TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?>

<TODO Are there energy efficiency compliance requirements for the USA?>

<TODO what do we have to do to demonstrate RoHS compliance?>

Test reports certifying to standard UL/IEC 62368-1

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Safety-certifications

UL

<TODO UL Listing>

TODO

TODO

Electromagnetic compatibility (Emissions)

Test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B, and Industry Canada ICES-003

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Flow-Gateway-(device)%2C-including-Two-grouphead-Flow-meter-cables.1

Energy efficiency

External power supply certified to US Department of Energy (DOE) External Power Supply (EPS) standard - Level VI

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#USA-DOE-Compliance-Certification-Database

Restriction of Hazardous Substances (RoHS)

Certificates / declarations for input components, demonstrating compliance with the EU RoHS Directive 2011/65/EU (Compliance with the EU directive is required by some states in the USA)

https://flowcoffee-co-nz.atlassian.net/wiki/spaces/FGDC/pages/430440457/Supporting+evidence#Restriction-of-Hazardous-Substances-(RoHS)-declarations

TODO