Category | Component | Requirement | Status | Supporting evidence | Last updated |
---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device | Product description | |||
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with <TODO EMC Tech referenced “AS/NZS CISPR 32” or Spectrum lab referenced “EN 55032: 2015 + A11”?> | |||
Electromagnetic compatibility | Flow Gateway device | SDoC (Supplier Declaration of Conformity) | |||
Electromagnetic compatibility | External power supply | OEM provided SDoC (Supplier Declaration of Conformity) | |||
Electromagnetic compatibility | Flow Gateway device with external power supply | Registration with ERAC (Electrical Regulatory Authorities Council) in the ACMA (Australian Communications and Media Authority) section | |||
Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with AS/NZS 62368.1:2018 | |||
Electrical safety | External power supply | OEM provided test report demonstrating compliance with AS/NZS 62368.1:2018 or AS/NZS 60950.1:2015 <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current test report and/or documents for AU?> | |||
Electrical safety | External power supply | Registration with EESS (Electrical Equipment Safety System) | |||
Energy efficiency | External power supply | Registration with E3 Program (Equipment Energy Efficiency) | |||
<TODO is RoHS required for AU/NZ, and if so what do we have to do to demonstrate RoHS compliance?> |
Product marking
...
Category
...
Component
...
Mark
...
Electromagnetic compatibility / Electrical safety
...
Flow Gateway device
...
RCM (Regulatory Compliance Mark)
...
Electromagnetic compatibility / Electrical safety
...
External power supply
...
RCM (Regulatory Compliance Mark)
...
Energy efficiency
...
External power supply
...
External power supply efficiency level mark
...
<TODO Is a RoHS mark required for the device, and if so which one?>
...
<TODO Is a RoHS mark required for the power supply, and if so which one?>
Europe / UK
Requirements
Category | Component | Requirement | Status | Supporting evidence | Last updated |
---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with EN 55032:2015+A11 | |||
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility immunity test report demonstrating compliance with EN 55035:2017 | |||
Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with EN 62368-1:2020 | |||
Electromagnetic compatibility and Electrical safety | Flow Gateway device | CE Declaration of Conformity for electromagnetic compatibility and electrical safety | |||
Electrical safety | External power supply | OEM provided CE Declaration of Conformity for electromagnetic compatibility and electrical safety <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides a current CE Declaration of Conformity?> | |||
<TODO What are there energy efficiency compliance requirements for the EU?> | |||||
<TODO what do we have to do to demonstrate RoHS compliance?> | |||||
<TODO Is the device required to be WEEE compliant (or just the power supply)?> | |||||
<TODO what do we have to do to verify the power supplies WEEE compliance?> |
Product marking
Category | Component | Mark | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Electromagnetic compatibility / Electrical safety | Flow Gateway device | CE | ||||||||
Electromagnetic compatibility / Electrical safety | External power supply | CE | <Is External power supply efficiency level mark required?> | <Is WEEE mark required for device> | <Is WEEE mark required for power supply> |
USA / Canada
Requirements
Category | Component | Requirement | Status | Supporting evidence | Last updated |
---|---|---|---|---|---|
Electromagnetic compatibility | Flow Gateway device with external power supply | Electromagnetic compatibility emissions test report demonstrating compliance with CFR (Code of Federal Regulations) Title 47, Part 15, Subpart A and Subpart B | |||
Electromagnetic compatibility | Flow Gateway device | FCC SDoC (Supplier Declaration of Conformity) | |||
Electromagnetic compatibility | External power supply | OEM provided FCC SDoC (Supplier Declaration of Conformity) | |||
Electromagnetic compatibility | Flow Gateway device with external power supply | Display required FCC warnings in the user manual <TODO what are the required FCC warnings?> | |||
Electrical safety | Flow Gateway device | Electrical safety test report demonstrating compliance with UL 62368-1:2019 | |||
<How do we demonstrate that the external power supply complies with the electrical safety requirements?> <TODO Spectrum lab notes that the power supply was tested to 60950-1 not 62368-1, is this a problem if the manufacturer still provides current documentation (SDoC/UL registration?)?> | |||||
<TODO Are there energy efficiency compliance requirements for the USA?> | |||||
<TODO what do we have to do to demonstrate RoHS compliance?> |
Product marking
Category | Component | Mark | <If we don’t need to register the device with FCC, can/should we use the FCC mark on the device still?> | ||||||
---|---|---|---|---|---|---|---|---|---|
Electromagnetic compatibility | External power supply | FCC | |||||||
<TODO is a electrical safety mark (UL?) required for the device> | <TODO what electrical safety mark (UL?) is required for power supply> | <Is External power supply efficiency level mark required?> | <TODO Is the RoHS mark required for device, and if so which one?> | <TODO Is the RoHS mark required for power supply, and if so which one?> |