Disconnect the coffee machine’s plug or quick connect (blade) connectors from the flow meter terminals.
Connect the female connector on the Flow meter cable to the flow meter terminals.
Connect the corresponding male connector on the Flow meter cable to the coffee machine’s plug or quick connect (blade) connectors.
Unused connection
If there is a spare connector on the Flow meter cable after all groupheads have been connected (ie. when two cables are used for a 3 grouphead coffee machine), connect the spare male and female plugs together then secure the cable out of the way.
Nb. If space constraints inside the coffee machine prevent the plug on the Flow meter cable from being able to be connected to the coffee machine’s flow meter, the orientation of the cable entry sleeve on the connector can be rotated. To do this:
...
Unscrew the cable entry grommet, so that the cable can move freely.
...
Pop the pinout insert out of the bottom of the connector by removing the centre screw and pressing down on the flange which surrounds the screw.
...
Rotate the pinout insert to the desired orientation and reinsert it into the plug housing, taking care not to crush any of the wires on the centre screw flange.
...
Coffee machine flow meter connector variations
...